Feature Type
Thermal Boundaries delimit Thermal Zones. Thermal Boundaries represent physical relationships between two Thermal Zones, or a Thermal Zone and the outside environment, or a Thermal Zone and the ground. Their non-opening construction must be homogeneous.
Attribute type: core:creationDate |
Date the city object was generated.
0..1
Date
Attribute type: core:terminationDate |
????
0..1
Date
Attribute type: core:externalReference |
Reference to a corresponding object in another information system, for example in the German cadastre (ALKIS), the German
topographic information system (ATKIS), or the OS MasterMap®.
0..*
ExternalReference (DataType)
Attribute type: core:relativeToTerrain |
Location of the city object relative to the surrounding terrain.
0..1
RelativeToTerrain (Enumeration)
Code |
Text |
|
entirelyAboveTerrain |
entirelyAboveTerrain |
Object is located entirely above terrain.
|
substantiallyAboveTerrain |
substantiallyAboveTerrain |
Most, but not all parts of the object are located above terrain.
|
substantiallyAboveAndBelowTerrain |
substantiallyAboveAndBelowTerrain |
Parts of the object are located above terrain, and other parts below terrain.
|
substantiallyBelowTerrain |
substantiallyBelowTerrain |
Most, but not all parts of the object are located below terrain.
|
entirelyBelowTerrain |
entirelyBelowTerrain |
All parts of the object are located below terrain.
|
Attribute type: core:relativeToWater |
Location of the city object relative to the surrounding water surface.
0..1
RelativeToWater (Enumeration)
Code |
Text |
|
entirelyAboveWaterSurface |
entirelyAboveWaterSurface |
Object is located entirely above water surface..
|
substantiallyAboveWaterSurface |
substantiallyAboveWaterSurface |
Most, but not all parts of the object are located above water surface.
|
substantiallyAboveAndBelowWaterSurface |
substantiallyAboveAndBelowWaterSurface |
Parts of the object are located above water surface, and other parts below water surface.
|
substantiallyBelowWaterSurface |
substantiallyBelowWaterSurface |
Most, but not all parts of the object are located below water surface.
|
entirelyBelowWaterSurface |
entirelyBelowWaterSurface |
All parts of the object are located below water surface.
|
temporarilyAboveAndBelowWaterSurface |
temporarilyAboveAndBelowWaterSurface |
The height of the water surface is varying and the object temporily is located above or below water level.
|
Attribute type: core:appearance |
0..*
AbstractAppearance
Attribute type: core:genericAttribute |
Additional property of the city object
0..*
AbstractGenericAttribute (DataType)
Attribute type: energy:thermalBoundaryType |
Topological classification of the thermal boundary.
1
ThermalBoundaryTypeValue (Enumeration)
Code |
Text |
|
InteriorWall |
InteriorWall |
Vertical partition separating two Thermal Zones of the same building. |
IntermediaryFloor |
IntermediaryFloor |
Horizontal partition separating two Thermal Zones of the same building. |
SharedWall |
SharedWall |
Vertical partition separating two different buildings. |
OuterWall |
OuterWall |
Vertical Thermal Boundary with one side facing outdoor. |
GroundSlab |
GroundSlab |
Lower horizontal Thermal Boundary of the Thermal Zone, built ditectly on the ground. |
BasementCeiling |
BasementCeiling |
Horizontal partition separating the basement floor and the ground floor. |
AtticFloor |
AtticFloor |
Horizontal partition separating the attic and the highest full storey. |
Roof |
Roof |
Thermal Boundary corresponding to the CityGML RoofSurface. |
Attribute type: energy:azimuth |
Azimuth angle of the normal surface vector.
By convention:
- azimuth = 0 for north orientation.
- Horizontal surface
have a azimuth = 0.
0..1
Angle
Attribute type: energy:inclination |
Inclination angle of the normal surface vector.
By convention, inclination = 0 for horizontal plane.
0..1
Angle
Attribute type: energy:area |
Total area of the Thermal Boundary, inclusive the included opening area
0..1
Area (Type)
Attribute type: energy:surfaceGeometry |
0..1
GM_MultiSurface (Type)
Attribute type: energy:refurbishmentMeasureOnThermalBoundary |
Reference designation of the degree of refurbishment. This reference may be European (from the Tabula project) or local (used for the Energy Action Plan of a city).
0..*
RefurbishmentMeasure
Attribute type: energy:staticConstruction |
Construction of the static part of the Thermal Boundary (i.e. the non-opening building elements), If the referenced Construction/ConstructionOrientation
object has more than one layer, the following rules for the layer order apply:
0..1
AbstractConstruction
Attribute type: energy:contains |
0..*
ThermalOpening
Attribute type: energy:delimits |
In case two ThermalZones are referenced via the relation "delimits", the following rule concerning the order of the related
objects applys:
- For ThermalBoundary objects of type "intermediaryFloor!, the first related object is the upper
ThermalZone, and the seconr related object is the lower ThermalZone
- For all other ThermalBoundary types, the first
related ThermalZone is in contact with the last Layer of the corresponding AbstractConstruction, and the second related ThermalZone
is in contact with the first Layer of the corresponding AbstractConstruction,
1..2
ThermalZone
Attribute type: energy:relatesTo |
Reference of a ThermalBoundary to the corresponding physical boundary surface of the building
0..*
_BoundarySurface